Rockchip RK3576 + Anlogic FPGA + CL1616 ×4:64 channels Data Acquisition Solution
A 64-channel synchronized data acquisition reference combining a Rockchip RK3576, an Anlogic FPGA and four CL1616 front-ends. Sampling and timing are kept separate from processing and the Qt waveform display, so precise acquisition is not tied to the user interface.
When electronica 2026 in Munich ended after November 13, Forlinx had drawn wide attention with the product solutions on its stand. One of them was a 64-channel synchronized data acquisition reference that combines an RK3576 with an FPGA and sampling front-ends. This series turns the spotlight on how the design separates precise sample timing from processing and waveform display.
An industrial monitoring application may need to compare several electrical signals, not merely collect them. If channels describe different moments, the displayed values can be difficult to interpret together. Forlinx's RK3576 AMP and FPGA demonstration addresses this system problem through a division of acquisition, processing and visualization responsibilities.
In the published 64-channel demonstration, an FPGA coordinated synchronized acquisition, a real-time processing component handled the samples, and a Linux interface displayed waveforms and frequency information. The design offers a reference for power monitoring projects in which the timing relationship between signals matters.
Solution configuration at a glance
The solution brief describes a cooperative architecture built on a Rockchip RK3576, an Anlogic FPGA and four CL1616 sampling front-ends. The front-ends provide 64-channel synchronous acquisition at 256 samples per cycle; the FPGA handles SPI control, synchronized acquisition and preprocessing, and a DSMC high-speed bus carries samples to an AMP real-time core (CPU3) that performs a 256-point real-time FFT. Dual-core communication and shared memory pass time- and frequency-domain data to a Linux and Qt interface that refreshes all 64 waveforms.
Listed applications are multi-bay monitoring for ring main unit DTUs, transient grounding identification for power protection and high-precision power monitoring at industrial sites. The stated advantages are real-time sampling with 256 points per cycle across 64 channels, the DSMC bus between AMP and FPGA, and low-latency core-to-core exchange through AMP-Linux shared memory. These are the reference design's claims; the analog front end, isolation and measurement accuracy still need to be matched to the instrument being built.
Keep timing tasks separate from the user interface
A display needs to remain readable and responsive, but it is not the same task as establishing when samples are acquired. The FPGA handles coordinated acquisition in the reference workflow. The processor then deals with the resulting information and its presentation. AMP refers to an asymmetric multiprocessing arrangement in which processing responsibilities are assigned separately.
This division helps a team reason about the system. A screen refresh can be adjusted for usability without treating it as the sampling clock. Likewise, data handling should be designed around acquisition volume rather than how many points are visible on screen. The roles are related, but they should be specified independently.
Size the data path before choosing the display
A project should state channel count, sample rate, sample width and how long data must be retained. As an illustrative sizing calculation, 64 channels at 10,000 samples per second and 16 bits per sample produce 1.28 MB per second of raw sample data, before metadata and transfer overhead. These assumed values explain the calculation; they are not measured performance claims for the demonstration.
The same method can be applied to the actual project. Buffering, transfer overhead and bursts need consideration alongside average throughput. This is how a team can identify whether the data path or storage plan deserves attention before optimizing the interface.
Turn acquired data into useful monitoring information
Waveforms show changes over time, while frequency information provides another view of the signal. The intended operator task should determine which displays and calculations are needed. A product may also require event markers or selected recording windows, but those are functions to specify and validate rather than assume from the booth screen.
Power equipment monitoring and industrial test systems are possible application directions. The complete instrument design should match the acquisition architecture to its analog front end, isolation, measurement accuracy and installation requirements.
A monitoring prototype with separate update rates
Consider equipment monitoring that needs continuous sample collection but a screen that updates at a rate comfortable for an operator. The prototype can keep the acquisition path running while the processing task prepares selected information for display. The raw data requirement and the display update requirement are specified independently.
The advantage of the task split is clearer ownership of timing and information flow. Engineers can investigate an acquisition issue without confusing it with a slow screen refresh, and can improve the presentation without redefining the measurement objective. The actual buffering and transfer scheme must be chosen around the required sample rate and available hardware.
Define a reproducible acquisition evaluation
Bring the analog input requirements, sample format and processing goals to Forlinx. We can discuss the RK3576 platform and the hardware integration around that acquisition brief. The 64-channel demonstration is a system reference involving an FPGA and associated hardware, providing a practical basis for defining the next prototype.
Frequently Asked Questions
What hardware makes up the 64-channel synchronized acquisition design?
The solution brief describes a cooperative architecture built on a Rockchip RK3576, an Anlogic FPGA and four CL1616 sampling front-ends. The front-ends provide 64-channel synchronous acquisition at 256 samples per cycle.
What does the FPGA handle in this design?
The FPGA handles SPI control, synchronized acquisition and preprocessing, while a DSMC high-speed bus carries samples to an AMP real-time core.
How are the real-time FFT and waveform display implemented?
The AMP real-time core (CPU3) performs a 256-point real-time FFT. Dual-core communication and shared memory pass time- and frequency-domain data to a Linux and Qt interface that refreshes all 64 waveforms.
What applications are listed for the 64-channel system?
Listed applications are multi-bay monitoring for ring main unit DTUs, transient grounding identification for power protection and high-precision power monitoring at industrial sites. The analog front end, isolation and measurement accuracy still need to be matched to the instrument being built.